Pump installed | MWK Cascade magnet pump, ultimate pump for equipment use |
---|
The compact and lightweight cascade magnet pump can be integrated into machines and contributes greatly for reducing the machine's size.
The standard motors coupled are approved by UL, CE marking, CSA standard, and EP ACT.
We have delivered more than 3,000 units to the semiconductor manufacturing industry, and earned a good reputation.
The head and motor terminal box can be positioned freely as this unit separates the motor from the pump.
Standard stock for 0.55kW to 3.0kW models.
Totally enclosed fan cooled, outdoor type
Type | Total head(m) | Capacity (L/min) | Motor kW | Liquid name | Temperature | Viscosity | Specific gravity |
---|---|---|---|---|---|---|---|
MWK | 28 | 5 | 0.55 | Pure water | 1 | 1 | |
MWK | 30 | 8 | 1.1 | GALDEN | 1 | 1.8 | |
MWK | 30 | 20 | 1.5 | GALDEN | 1 | 1.8 | |
MWK | 40 | 30 | 3 | GALDEN HT135 |
1 | 1.8 | |
MWK | 30 | 20 | 1.1 | FC-3283 | 80 | 1.83 | |
MWK | 30 | 20 | 1.1 | FC-3283 | 80 | 1.83 | |
MWK | 28 | 5 | 0.55 | Pure water | 1 | 1 | |
MWK | 28 | 5 | 0.55 | Pure water | 1 | 1 | |
MWK | 45 | 27 | 1.5 | Pure water, EG | 1 | 1 | |
MWK | 40 | 30 | 2.2 | GALDEN HT135 |
40 | 1 | 1.8 |
MWK | 40 | 30 | 1.5 | Ethylene glycol | 80 | 7 | 1.05 |
MWK | 30 | 20 | 1.1 | FC-3283 | 80 | 1.83 |
Results of typical liquids | ・GALDEN (HT135, HT200, HT230, etc.) ・Fluorinert (FC3283, FC40, etc.) ・NOVEC (HFE7100, HFE7200, etc.) ・Ethylene glycol, Pure water, etc. |
---|---|
Typical usages | ・Chiller for semiconductors and LCD, various washing systems. ・Temperature controller for metal mold ・ Dryer and various fine chemicals |
|