Pump installed | MET META series. ISO2858 compliant magnet drive pump |
---|
Our pump is compatible with the ISO2858 (JIS B 8313,16bar) standard seal pumps, so you can make your line sealless without needing any piping or base engineering work.
Examples of using a seal-less pump for transferring caustic soda that decreased maintenance work and solved an environmental problem.
This MET model pump is compatible with our IC model and pumps (conforms to ISO2858 (JIS B 8313,16bar) made by other manufacturers. The pumps can be converted to magnet pumps by replacing the rotors on site.
The cost of the magnet pump itself is also 30% less. (Compared with our conventional models)
Seal pump | Magnet pump | |
---|---|---|
(Sanwa Hydrotech) Model name | IC80x50-160 | MET80x50-160U |
Shaft seal | Mechanical seal | Seal-less |
Efficiency | 62% | 58% |
BHP (Shaft power) | 8.0kW | 8.6kW |
Motor specifications | 11kWx2Px50Hz | 11kWx2Px50Hz |
Pump material (liquid contacting parts) | SCS14/SUS316 | SCS14/SUS316 |
Flushing water (cooling water) | 1,800ton/year(=> Approximately 60,000 yen) | No need |
Mechanical seal | parts cost / year (=> Approximately 80,000 yen) | No need |
Check (maintenance) fee and others | Approximately 150,000 yen per year | Approximately 10,000 yen per year |
Power cost (electricity) | Approximately 256,000 yen per year (In case of 8.0 kW) |
Approximately 275,000 yen per year (In case of 8.6kW pump) |
Total running cost | 546,000 yen / year | 285,000 yen / year (Saving approximately 261,000 yen per year) |
MET (Rotating section only) Initial cost | ~ | Approx. 400,000 yen |
The cost will decrease after approximately 1.5 years, since the conventional pumps were converted to magnet pumps.
In addition, using the magnet pump longer will further increase saving.
Converted to seal-less |
"Caustic soda crystallizes when it leaks. On a mechanical seal pump, the sliding surface and secondary seals are covered by the solid and this may damage the mechanical seal and cause a malfunction. This can cause another leaks. As a result, the bracket and base corrode, we paid for lots of maintenance hours and maintenance cost.
After we started using a magnet drive pump, the liquid leak were completely eliminated and our maintenance cost decreased greatly. Also, the magnet pump contributed a lot to the environment and working conditions. In the future, we are planning to replace our conventional pumps with magnet pumps.
<From a maintenance department staff of a chemical company>
At present, mechanical seals and glound packing are used for pumps for caustic soda.
When caustic soda leaks, it crystallizes and shortens service live of the mechanical seal.
Therefore, users who have pumps with mechanical seals need to replace them once or twice a year, and their maintenance tend to be expensive.
There are lots of users using ground picking who are worried about the environmental problems, such as daily leaks and stain on bases.
In order to solve all of the problems, including a large number of maintenance hours, plus other maintenance and repair costs, and resolve the environmental problems, we recommend our seal-less type magnet drive pumps